2010 Acura Truck MDX V6-3.7L Page 252


9. Turn the ignition switch to LOCK (0).



10. Disconnect driver's MPCS unit connector B (14P).



11. Disconnect the 6P connector from the driver's power window motor.



12. Check for continuity between driver's MPCS unit connector B (14P) terminal No. 5 and driver's power window motor 6P connector



terminal No. 4.



Is there continuity?



YES -



Go to step 13.



NO -



Repair an open in the wire.?



13. Check for continuity between driver's power window motor 6P connector terminal No. 4 and body ground.



Is there continuity?



YES -



Repair a short in the wire.?



NO -



Go to step 14.



14. Do the driver's power window motor test See: Windows and Glass/Windows/Power Window Motor/Testing and Inspection/Driver's Power



Window Motor Test.



Is the motor OK?



YES -



Replace the driver's MPCS unit.?



NO -



Replace the driver's power window motor.?



15. Check for continuity between driver's MPCS unit connector B (14P) terminals No. 3 and No. 6 and the driver's power window motor 6P